Print Page
Image is for illustrative purposes only. Please refer to product description.
ManufacturerLEM
Manufacturer Part NoDVL 150-UI
Order Code2664165
Product RangeDVL-UI Series
Your Part Number
Technical Datasheet
4 In Stock
Need more?
4 Delivery in 5-6 Business Days(UK stock)
| Quantity | Price (inc GST) |
|---|---|
| 1+ | CNY3,612.810 (CNY4,082.4753) |
| 5+ | CNY3,161.200 (CNY3,572.156) |
| 10+ | CNY2,619.290 (CNY2,959.7977) |
| 25+ | CNY2,348.330 (CNY2,653.6129) |
| 50+ | CNY2,301.360 (CNY2,600.5368) |
| 100+ | CNY2,254.400 (CNY2,547.472) |
Price for:Each
Minimum: 1
Multiple: 1
CNY3,612.81 (CNY4,082.48 inc GST)
Line Note
Added to your Order Confirmation, Invoice, and Dispatch note for this order only.
Product Information
ManufacturerLEM
Manufacturer Part NoDVL 150-UI
Order Code2664165
Product RangeDVL-UI Series
Technical Datasheet
Transducer FunctionVoltage Transformer
Supply Voltage Min-13.5V
Measured VoltageAC, DC, Pulsed
Supply Voltage Range± 13.5V to ± 26.4V
Supply Voltage Max26.4V
Accuracy0.5%
Primary Voltage Nom150V
Accuracy± 1%
Secondary Signal Type4mA to 20mA
Input Current25mA
Sensor Output TypeAnalog
External Depth100mm
Sensor MountingPanel Mount
Output Current Max21mA
Operating Temperature Min-40°C
Operating Temperature Max85°C
Linearity %0.5%
Product RangeDVL-UI Series
SVHCNo SVHC (25-Jun-2025)
Product Overview
DVL 150-UI is a DVL-UI series voltage transducer for the electronic measurement of voltage: DC, pulsed, with galvanic separation between the primary and the secondary circuit. Standards include EN 50155: 2021, EN 50178: 1997, EN 50124-1: 2017, EN 50121-3-2: 2016, UL 508: 2013. Applications include substations and trackside.
- 4-20mA output
- Input and output connections with M5 studs
- Compatible with AV 100 family
- Low consumption and low losses, compact design
- Good behaviour under common mode variations, excellent accuracy (offset, sensitivity, linearity)
- Good delay time, low temperature variation, high immunity to external interferences
- 150V primary nominal DC voltage at TA = 25°C, ±UC = ±24V, RM = 100 ohm
- 100ms rise time of UC (10 ‒ 90%) at TA = 25°C, ±UC = ±24V, RM = 100 ohm
- 30mA max current consumption at UC = ±24V at UP = 0V
- Ambient operating temperature range from -40 to 85°C
Technical Specifications
Transducer Function
Voltage Transformer
Measured Voltage
AC, DC, Pulsed
Supply Voltage Max
26.4V
Primary Voltage Nom
150V
Secondary Signal Type
4mA to 20mA
Sensor Output Type
Analog
Sensor Mounting
Panel Mount
Operating Temperature Min
-40°C
Linearity %
0.5%
SVHC
No SVHC (25-Jun-2025)
Supply Voltage Min
-13.5V
Supply Voltage Range
± 13.5V to ± 26.4V
Accuracy
0.5%
Accuracy
± 1%
Input Current
25mA
External Depth
100mm
Output Current Max
21mA
Operating Temperature Max
85°C
Product Range
DVL-UI Series
Technical Docs (3)
Legislation and Environmental
Country of Origin:
Country in which last significant manufacturing process was carried outCountry of Origin:Bulgaria
Country in which last significant manufacturing process was carried out
Country in which last significant manufacturing process was carried outCountry of Origin:Bulgaria
Country in which last significant manufacturing process was carried out
Tariff No:85043121
US ECCN:EAR99
EU ECCN:NLR
RoHS Compliant:Yes
RoHS
RoHS Phthalates Compliant:Yes
RoHS
SVHC:No SVHC (25-Jun-2025)
Download Product Compliance Certificate
Product Compliance Certificate
Weight (kg):.29